Power Distribution System SVS02 Description The E-T-A power distribution system SVS02 is designed to accommodate the electronic circuit breaker series ESS20-003 or electronic circuit protector ESX10. It distributes the current supplied by a switch mode power supply up to 40 A to 4, 8, 12 or 16 channels. Input connections are via screw terminals. The individual circuit breakers can be plugged in. Loads are connected via spring-loaded screwless terminals. The power distribution includes integral wiring of the signalisation of the individual channels which can be combined to a group signal. The SVS02 can be snapped onto a DIN symmetrical rail. Suitable for Ordering information Technical data Type SVS02 Power distribution system for ESS20-003 ● short circuit current limited DC 24 V applications ● max. 40 A continuous load ● two integral circuit breakers (CB1 and CB2): overcurrent protection of group signalisation of power distribution system, red LED glashes upon trip of CB1 ● 2 insulated wire bridges Y 303 881 08 included ● without jumpers SB-S11-P1-01-1-1A (for unused positions) Version, max. number of circuit breakers ESS20-003 on the power distribution system 04 4 channels (F1...F4) 08 8 channels (F1...F8) 12 12 channels (F1...F12) 16 16 channels (F1...F16) Screw terminals for power supply DC 24 V P310 3 loop-through terminals (X 21) max. 10 mm2 for DC 24 V (+) / DC 24 V (-) / FE functional earth Load outputs per channel (F1 .. Fn, n = 04, 08, 12, 16) L50 5 load outputs per channel, max. 8 A each ● (L+S) group output (+) internally bridged over all channels ● (L+L) protected load output (+), per channel ● (-) DC 24 V (-) ● (-) DC 24 V (-) ● (FE) functional earth Signal outputs S15 1 signal terminal (X31) for group signal, 5-pole, complete with plug-in terminal, wiring 5 x max. 2.5 mm2 / without connector sleeve, max. 0.5 A: ● (+) internal +DC 24 V supply for signalisation via insulated wire bridge from (+) to (SC) ● (SC) external supply possible +DC 24 V for signalisation ● (S0) signal output group signalisation ● (-) additional output DC 24 V (-) ● (FE) additional functional earth Control input E00 without control input Fitting variants B10 complete with screwless spring-loaded terminals, (max. 2.5 mm2, without connector sleeve) (standard) B20 complete with plug-in screw terminals (max. 2.5 mm2, without connector sleeve) Modular Power distribution system for short-circuit limited DC 24 V applications up to max. 40 A continuous load, max. voltage DC 32 V. Three screw terminals (max. 10 mm2/AWG 8) for: - DC 24 V (+) = X 21 + - DC 24 V (-) = X 21 - FE (functional earth) = X 21 FE for connecting the DC 24 V power supply max. 40 A Modular design ESS20-positions F1...F4 (..F8, ...F12 or ...F16): - SVS02-04 / 4 channels / F1...F4 = Kl. X1...X4 - SVS02-08 / 8 channels / F1...F8 = Kl. X1...X8 - SVS02-12 / 12 channels / F1...F12 = Kl. X1...X12 - SVS02-16 / 16 channels / F1...F16 = Kl. X1...X16 5 load outputs per channel complete with Combicon screwless connectors, wiring 5 x max. 2.5 mm2 (AWG 14)/ without connector sleeve max. 8 A: - (L+S) group output (+), internally bridged across all channels - (L+L) load output (+), per channel - (-) DC 24 V (-) - (-) DC 24 V (-) - (FE) functional earth Signal terminal (X31) for group signal complete with Combicon screwless connectors, wiring 5 x max. 2.5 mm2 (AWG 14)/ without connector sleeve, max. 0.5 A (signal contact ESS20): - (+) internal +DC 24 V supply for signalisation of terminal X 21 + via insulated jumper from (+) to (SC), protected by CB2 - (SC) external supply possible +DC 24 V for signalisation, protected by CB1 - (S0) signal output group signalisation - (-) additional output DC 24 V (-) - (FE) additional functional earth Selective overcurrent protection CB1 and CB2 for group signalisation of the power distribution system, red LED blinks after CB1 has tripped (see schematic diagram). Reset of circuit breakers: momentarily press red actuator button Protection class to: IP20 Insulation co-ordination to IEC 60934: 0.5 kV / pollution degree 2 Dielectric strength AC 500 V Temperature range: 0...50 °C (without condensation) for DIN symmetrical rail mounting EN 50022 - 35 x 7.5 Dimensions: see dimensional drawing

 Abrir la página 1 del catálogo

Power Distribution System SVS02 Dimensions SVS02-16 Insulated wire bridge, not fitted (2 pcs enclosed) CB1 RESET NUR KURZ DRUECKEN ONLY PUSH BRIEFLY red LED blinks after CB1 has tripped screw terminals DC 24 V power supply load outputs screwless spring-loaded terminals This is a metric design and millimeter dimensions take precedence ( mm ) inch *) see application example for insulated wire bridge X31 .1 LED V1 blinks after CB1 has tripped CB2: no visual indication Circuit breakers CB1 and CB2: shown in tripped condition

 Abrir la página 2 del catálogo

Power Distribution System SVS02 Dimensions SVS02-04, fitted with ESS20-003 red LED blinks after CB1 has tripped Elektronischer Schutzschalter Electronic Supplementary Protector Insulated wire bridge, not fitted (2 pcs enclosed) RESET NUR KURZ DRUECKEN ONLY PUSH BRIEFLY screw terminals DC 24 V power supply load outputs screwless spring-loaded terminals This is a metric design and millimeter dimensions take precedence ( mm ) inch

 Abrir la página 3 del catálogo

Power Distribution System SVS02 Dimensions SVS02-04, fitted with ESX10-103 Insulated wire bridge screw terminals power supply load outputs screwless spring-loaded terminals

 Abrir la página 4 del catálogo

Power Distribution System SVS02 Application example for jumper to replace Application example for insulated wire bridge The signalling pathway of the group signalisation is as follows: - feed-in of +DC 24 V potential in (SC = terminal 31.2) - via in-built overcurrent protection CB1 - via all signal contacts of the fitted circuit breakers type ESS20-003 - back to signal output of group signalisation (S0 = terminal 31.3) Terminal X31 (group signalisation) wire bridge from (+) to (SC) internal +DC24V feed for signalisation Thus plus potential of terminal X21+ is connected to (SC) In operating condition...

 Abrir la página 5 del catálogo

Todos los catálogos y folletos técnicos E-T-A

  1. Economy Power-D-Box

    4 Páginas

    En
  2. High Power-D-Box

    4 Páginas

    En
  3. SVS14

    6 Páginas

    En
  4. SVS15

    8 Páginas

    En
  5. SVS18

    6 Páginas

    En
  6. 1140-E

    4 Páginas

    En
  7. 1110

    2 Páginas

    En
  8. 129-L11-H-KF

    2 Páginas

    En
  9. 127

    4 Páginas

    En
  10. 104

    4 Páginas

    En
  11. SVS16-PB

    6 Páginas

    En
  12. SVS20

    8 Páginas

    En

Catálogos archivados

  1. Level Sensors

    20 Páginas

    En