Tetra 30/50 Technical Data Standard: Tetra-30-LF / Tetra-50-LF 1. Dimensions of cabinet (19“ Rack): without connections: Tetra-30: approx. W 600mm x H 1800 mm x D 800 mm Tetra-50: approx. W 600mm x H 1800 mm x D 800 mm Weight: approx. 250 kg (without pump) 2. Dimensions of vacuum chamber: Tetra-30: approx. W 305 mm x H 300 mm x D 370 mm Tetra-50: approx. W 305 mm x H 300 mm x D 625 mm Chamber volume: approx. 33 l / 57 l 3. Gas connections: 2 gas channels through needle valve 4. Plasma generator: 40 kHz / 0 – 1.000 W, infinitely variable 5. Electrodes and goods-carriers: The machine can be...
Abrir la página 2 del catálogoTechnical Data Standard: Tetra-30-LF-PC / Tetra-50-LF-PC 1. Dimensions of cabinet (19“ Rack): Tetra-30: approx. W 600mm x H 1800 mm x D 800 mm Tetra-50: approx. W 600mm x H 1800 mm x D 800 mm Weight: approx. 250 kg (without pump) 2. Dimensions of vacuum chamber: Tetra-30: approx. W 305 mm x H 300 mm x D 370 mm Tetra-50: approx. W 305 mm x H 300 mm x D 625 mm Chamber volume: approx. 33 l / 57 l 3. Gas connections: 2 gas channels through mass flow controller 4. Plasma generator: 40 kHz / 0 – 1.000 W, infinitely variable 5. Electrodes and goods-carriers: The machine can be equipped with one to...
Abrir la página 3 del catálogoTetra 100/150 Technical Data Standard: Tetra 100 LF / Tetra 150 LF 1. Dimensions of cabinet (19“ Rack): without connections: Tetra-100: approx. W 1000 mm x H 1800 mm x D 1000 mm Tetra-150: approx. W 1000 mm x H 2400 mm x D 1000 mm Weight: approx. 300 kg (without pump) 2. Dimensions of vacuum chamber: Tetra-100: approx. W 400 mm x H 400 mm x D 625 mm Tetra-150: approx. W 400 mm x H 600 mm x D 625 mm Chamber volume: approx. 100 l / 150 l 3. Gas connections: 2 gas channels through needle valve 4. Plasma generator: 40 kHz / 0 – 2.500 W, infinitely variable 5. Electrodes and trays: The machine...
Abrir la página 5 del catálogoTechnical Data Standard: Tetra 100 LF PC / Tetra 150 LF PC 1. Dimensions of cabinet (19“ Rack): Tetra-100: approx. W 1000 mm x H 1800 mm x D 1000 mm Tetra-150: approx. W 1000 mm x H 2200 mm x D 1000 mm Weight: approx. 300 kg (without pump) 2. Dimensions of vacuum chamber: Tetra-100: approx. W 400 mm x H 400 mm x D 625 mm Tetra-150: approx. W 400 mm x H 600 mm x D 625 mm Chamber volume: approx. 100 l / 150 l 3. Gas connections: 2 gas channels through mass flow controller 4. Plasma generator: 40 kHz / 0 – 2.500 W, infinitely variable 5. Electrodes and trays: The machine can be equipped with...
Abrir la página 6 del catálogoThe Fully Automatic Control: The fully automatic control was conceived for continuously running processes with only a few parameter changes. In contrast to the PC variant gas flow, pressure and power are only steered and not electronically regulated. By pushing the „Start“ button, the plasma process runs fully automatic: 1. Pump 2. Gas delivery 3. Power / Timer / Plasma process 4. Flushing 5. Ventilation There is also the possibility of starting and of terminating each sequence of the process manually. For this the buttons are successively operated. The PC-control: The PC-control was...
Abrir la página 7 del catálogo13.56 MHz generator 2.45 GHz generator intake filter for vacuum pump carbon exhaust filter automatic door barcode reader bias voltage measurement butterfly valves rotary drum (bulk goods, powder) pressure-reducing valve spare parts set faraday box gas shower heating plate ion measuring sensor corrosive gas version monomer bottle network connection PC-control polymerization accessories RIE electrode safety valve software (also customized) special flanges temperature sensors test inks vacuum pump systems device for powder treatment trays (also customized) service contract additional gas...
Abrir la página 8 del catálogoDiener electronic GmbH + Co. KG Talstr. 5 D-72202 Nagold (Germany) Telefon: +49 (0) 7452 / 888 07 - 0 Telefax: +49 (0) 7452 / 888 07 - 50 E-Mail: info@diener-electronic.de Visit our homepage: www.plasma.de degreasing / cleaning photoresist ashing hydrophilization hydrophobization oleophobization powder treatment pre-treatment before printing pre-treatment before bonding pre-treatment before painting pre-treatment before soldering pre-treatment before molding pre-treatment before casting pre-treatment before gluing . . . Analysis Archaeology Automotive industry Biotechnology Elastomer...
Abrir la página 9 del catálogoTodos los catálogos y folletos técnicos Diener electronic GmbH & Co. KG
-
RF 300
2 Páginas
-
RF 100
2 Páginas
-
DLC
3 Páginas
-
Tetra 150
6 Páginas
-
Tetra 100
6 Páginas
-
Parylene P300
2 Páginas
-
Parylene P260
2 Páginas
-
Parylene P120D
2 Páginas
-
Parylene P30
2 Páginas
-
Parylene P6
2 Páginas
-
Parylene
3 Páginas
-
Surface treatment Service
6 Páginas
-
Atto/Zepto
2 Páginas
-
APC 500
4 Páginas
-
MWG1200
2 Páginas
-
LFG5000
2 Páginas
-
LFG3000
2 Páginas
-
LFG1000
2 Páginas
-
LFG500
5 Páginas
-
Plasma Surface Technology
15 Páginas
-
PlasmaBeamMini
2 Páginas
-
PlasmaBeamDuo
6 Páginas
-
PlasmaBeam PC
6 Páginas
-
Special systems
36 Páginas
-
TETRA 30
6 Páginas
-
PlasmaBeam
6 Páginas
-
NANO
2 Páginas
-
PICO
2 Páginas
-
FEMTO
2 Páginas
-
Tetra 8
1 Páginas
-
PLASMA APC 500
1 Páginas
-
Plasma Technology Diener electronic
82 Páginas