3202 GB Motor SCM 012–130 Sunfab SCM is a range of robust axial piston motors especially suitable for mobile hydraulics. The SCM covers the entire Sunfab SCM is of the bent- SUNFAB SCM SAE 012034 features double tapered roller bearings, which permits high shaft loads and gives superb speed performance. displacement range 12-130 cm3/rev at a maximum working pressure of 40 MPa. axis type with spherical pistons. The design results in a compact motor with few moving parts, high starting torque and high reliability. Type SAE SUNFAB SCM SAE 040130 combines a tapered roller bearing and a radial bearing for high radial load tolerance and long life time. SUNFAB SCM’s high level of reliability is based on the choice of materials, hardening methods, surface structures and the quality assured manufacturing process. 012 017 025 034 040 047 056 064 084 084 090 090 108 108 130 SAE B SAE B SAE B SAE B SAE C SAE C SAE C SAE C SAE C SAE D SAE C SAE D SAE C SAE D SAE D Displacement cm3⁄rev. 12.6 17.0 25.4 34.2 41.2 47.1 56.7 63.5 83.6 83.6 90.7 90.7 108.0 108.0 130.0 Working pressure max. intermittent MPa 40 40 40 40 40 40 40 40 40 40 40 40 40 40 35 max. continuous MPa 35 35 35 35 35 35 35 35 35 35 35 35 35 35 30 Revolutions max. intermittent rpm 8250 8250 6500 6500 5900 5900 5900 5900 4800 4600 4800 4600 4800 4600 4600 max. continuous rpm 7500 7500 5900 5900 5300 5300 5300 5300 4400 4200 4400 4200 4400 4200 4200 min. continuous rpm 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 Power max. intermittent kW 50 70 80 110 120 135 165 180 200 190 215 205 255 245 255 max. continuous kW 20 25 40 55 60 65 80 90 100 100 110 110 130 130 135 Start torque theoretical value Nm ⁄ MPa 2.0 2.7 4.0 5.4 6.6 7.5 8.9 10.0 13.3 13.3 14.4 14.4 17.1 17.1 20.5 Mass moment of inertia ( x 10 -3) kg m2 0.9 0.9 1.1 1.1 2.6 2.6 2.6 2.6 6.3 7.4 6.3 7.4 6.3 7.4 7.4 Weight kg 9.0 9.0 9.0 9.0 15.0 15.0 15.0 15.0 18.0 35.0 18.0 35.0 18.0 35.0 35.0 Data concerning RPM are based on maximum premitted peripheral velocity of the tapered roller bearing. Intermittent power data are based on maximum continuous speed and maximum working pressure. Continuous power data are based on maximum output power without external cooling of the motor housing. 1 (11) Intermittent duty is defined as follows: max 6 seconds per minute, e g peak RPM when unloading or accelerating.
Abrir la página 1 del catálogoVersions, main data Example SC M Line - 012 1 W - N - SB4 - B13 - S3 U - 1 00 2 3 - 4 - 5 - 6 - 7 8 - 9 10 Line SC 7. Connection cover 012 017 025 034 040 047 056 064 084 090 108 130 Sunfab Compact, bent-axis design S1 40° Mount flange vertical* - - - - - - - - X X X X Motor S2 40° Mount flange horizontal* - - - - X X X X - - - - 2. Displacement S3 40° threaded connection X X X X - - - - - - - - V1 90° Mount flange vertical* - - - - - - - - X X X X V2 90° Mount flange horizontal* - - X X X X X X X X X X R1 Side connections, flanged* - - X X X X X X X X X X K3 Combicover 90° & side conn....
Abrir la página 2 del catálogoGeneral instructions Choice of shaft seal Temp. Max. housing pressure MPa at rpm Motor SCM Code °C 1000 2000 3000 4000 5000 012-034 B N 75 0.55 0.27 0.18 0.14 0.11 H 75 2.46 1.23 0.82 0.61 0.51 V 90 0.55 0.27 0.18 0.14 0.11 040-108 C N 75 0.55 0.27 0.18 0.14 0.11 H 75 2.46 1.23 0.82 0.61 0.51 V 90 0.55 0.27 0.18 0.14 0.11 084-130 D N 75 0.35 0.17 0.12 H 75 1.56 0.78 0.52 V 90 0.35 0.17 0.12 Subject to design modifications without notice Bearing life (h) Optimal force direction of radial load F Radial load (N) Shaft loads The life of the motor is highly dependent on the bearing life. The...
Abrir la página 8 del catálogoTemperatures/Housing cooling Q Excessive system temperature reduces the life of the shaft seal and can lower the oil viscosity below the recommended level. A system temperature of 60 °C and a drain flow temperature of 90 °C must not be exceeded. Qflush Counter pressure valve Cooling/flushing of the motor housing can be needed to keep the drain flow temperature at an acceptable level. Flushing l/min 2-8 4-10 6-12 Cont. RPM ≥ 2800 ≥ 2500 ≥ 2200 Counter pressure valve Suggested flow: Motor SCM 012-034 040-064 084-130 Qflush Flushing valve Qflush Housing flushing can be built up with the help...
Abrir la página 9 del catálogoUseful formulaes Required flow rate Q = Dxn 1000 x ηv Speed n = Q x 1000 x ηv D RPM Torque M = D x ∆p x ηhm 6,3 Nm Power P = Q x ∆p x ηt 60 litres⁄min. kW D = displacement, cm3⁄revolution n = speed, revolution⁄min P = power, kW Q = flow rate, litres⁄min ηv = volumetric efficiency ηhm = hydraulic-mechanical efficiency ηt = overall efficiency = ηv x ηhm M = torque, Nm ∆p = pressure difference between the hydraulic motor inlet and outlet, MPa 10 (11)
Abrir la página 10 del catálogoProduced in Sweden by Nova Design 3202GB1205 WARNING When the motor is in use: 1. Do not touch the pressure pipe 2. Beware of rotating parts 3. The motor and pipes can reach high temperatures Sunfab Hydraulics AB, Box 1094, SE-824 12 Hudiksvall, Sweden. Phone: +46 650-367 00, Fax: +46 650-367 27, E-mail: sunfab@sunfab.se Web: www.sunfab.com 11 (11)
Abrir la página 11 del catálogoTodos los catálogos y folletos técnicos Sunfab Hydraulics
-
SAM 010-130 DIN
7 Páginas
-
SCPD 76/76 DIN
4 Páginas
-
Catálogo de accesorios
28 Páginas
-
SVH 062, 092, 112
16 Páginas
-
SC 5012-5108 SAE
2 Páginas
-
SC 012-108 DIN
2 Páginas
-
filtro de aceite de aspiración
2 Páginas
-
válvula de descarga hidráulica
2 Páginas
-
depósito de aceite
2 Páginas
-
toma de fuerza dependiente del motor
4 Páginas
-
reductor con doble eje de salida
2 Páginas
-
bomba hidráulica de caudal variable
16 Páginas
-
bomba hidráulica para camión
2 Páginas
-
Caja distribuidora SZ 121
2 Páginas
-
SCM 047-090 M2
6 Páginas
-
Flushing Valve
2 Páginas
-
Speed Sensor
4 Páginas
-
DIODE GATE
2 Páginas
-
INJECTOR
2 Páginas
-
SVH 130
20 Páginas
-
SCM 012-130 DIN
7 Páginas
-
SCM 010-130 SAE
12 Páginas
-
SCM 010-130 ISO
12 Páginas
-
SAP 084, 108 DIN Optimised
4 Páginas
-
SAPT 090, 130 DIN
4 Páginas
-
SAP 012-108 DIN
4 Páginas
-
SLPD 40/20-64/32 SAE
4 Páginas
-
SLPD 20/20-64/32 DIN SAVTEC
5 Páginas
-
SLPD 20/20-64/32 DIN
4 Páginas
-
SCPD 56/26 DIN By-Pass
4 Páginas
-
SCPD 56/26 DIN
4 Páginas
-
SCM 025-108 M2
8 Páginas
-
SCM 012-130 SAE
12 Páginas
-
SCPT 090, 130 DIN
4 Páginas
-
SCP 012-130 ISO
7 Páginas
-
SCP 084, 108 DIN Optimised
4 Páginas
-
SAP 040-064 DIN
4 Páginas
-
SCP 012-108 DIN
4 Páginas
-
Product Catalogue
25 Páginas
Catálogos archivados
-
SCM Motor M2 034-108
6 Páginas
-
motor hidráulico de pistón axial
10 Páginas
-
ANTI-CAVITATION VALVE_2015
2 Páginas
-
Anti-Cavitation Valve_2012
2 Páginas